Reception
Floor-by-floor room map, occupancy, real-time incidents, setpoint overrides with reason (guest requests more heat, technician on site…) and automatic expiry.
THE SOLUTION
An integrated architecture connecting central HVAC plant, individual rooms or offices, and a web application designed around roles.
Together, we connect demand with the installation's response.
In a hotel, occupancy status can help adjust the climate in the rooms. That need can be coordinated with how the installation runs when the project includes the necessary signals, permissions and integration. At a campsite, the same approach adapts to accommodation units, zones and distributed equipment.
How they work togetherARCHITECTURE
D.System provides control and automation for building systems. Eco-Space connects the use of rooms, meeting spaces and zones with their climate control. The two solutions can work together depending on the equipment, signals and integrations available. For each project, we define where information is viewed, who can take action and which functions are included.
LAYER 01
The central layer integrates with the building's HVAC plant through proprietary wiring or over LoRaWAN, whichever fits best. It connects directly to the equipment (boilers, chillers, pumps, cooling towers, DHW, pools and common areas) or to the building's existing BMS. We review the interfaces and protocols of the existing equipment to determine what information we can read and which points we can act on.
LAYER 02
We use a wired connection where it is practical and consider LoRa where running new cables complicates the installation. Coverage, power supply and response times are checked at each location. We review the fan-coil model, its control and the signals available to define the integration. Window, key-card or presence inputs are incorporated when they are compatible and part of the agreed scope. Local autonomy on network loss, full app control whenever connectivity is available.
APPLICATION
The same platform shows each professional exactly what they need to see — without overwhelming, without hiding.
Floor-by-floor room map, occupancy, real-time incidents, setpoint overrides with reason (guest requests more heat, technician on site…) and automatic expiry.
Room-level technical detail: ambient and hydraulic-base temperature, anomalous ΔT, sensor battery, HVAC mode, action history, bulk actions per floor.
A view of recurring incidents, availability and consumption where metering exists. Indicators and comparisons are defined according to the data available and the agreed methodology.
Monitoring of consumption and operation according to the metering available. Savings indicators require an agreed baseline and comparison method; avoided hours alone do not establish kWh saved.
ALERTS AND NOTIFICATIONS
Every morning maintenance receives a report listing the rooms, offices or halls flagged with malfunctions in the last 24 hours. Without opening the app, the team already knows where to act.
With the signals available, we can set up alerts for alarms or behaviour that needs checking. We define the equipment monitored, the alert criteria and the maintenance staff's response.
Each technician picks the channel for each alert level. Critical messages never get lost, low-priority ones don't flood the on-call phone.
Every alarm is logged with equipment, timestamp and action taken. Useful for audits, certifications and spotting recurring failure patterns.
INTEGRATIONS
We study the connection with the site's management software, control platforms and existing equipment. Depending on the system, it can be done through available interfaces or an exchange file in an agreed format. We define the data, permissions, update frequency and the response if the information does not arrive.
DEPLOYMENT
MiniPC server in the building's technical room. Customer data stays under customer control. Recommended for clients with strict data policies.
Infrastructure managed by Eco-Space, with backups and maintenance included. Recommended for clients who prefer not to operate infrastructure.
Tell us what you need to control better and we'll explain how we could approach it in your installation.